Titan Mini (30kW)
In addition to the General Requirements mentioned here, the device specific requirements for DeCharge Titan Mini (30kW) device are as follows:
Mounting and Foundation
Concrete base prepared as per DeCharge installation blueprint
Safety clearance of at least 0.5 meters on all sides
Anchor bolts installed and visible
Canopy or shed installed for protection
Power Input Requirements
415V
50 KVA
35 sq.mm aluminium or 25 sq.mm copper
72A
Breaker panel must be within an accessible range
Neutral wire of 0.5 core must be connected using proper lugs
Neutral-to-earth voltage must be below 2V
Earthing
Two earthing pits required
Cabling: 25 x 3 mm tinned copper bus bar or 25 sq.mm single-core copper wire
Lugs: Ring-type aluminium or copper lugs for grounding points
Internet Connectivity
LAN: Cat6 cabling with proper termination and surge protection
4G/5G SIM: Valid SIM with strong signals
Wi-Fi: High-speed router, no competing devices, good coverage
Safety Infrastructure
Safety bollards installed
LED lighting in place
Fire suppression systems if required by local code
Security arrangements if in a commercial or public location
Documentation Required
Confirmation of grid connection or power availability
Approved CMS form with device mapping
Signature of host or location owner
Photographs of breaker, cables, and mounting area
Please fill out the interest-cum-pre-requisite form if you're interested in installing a 30kW Titan Mini DC Charger at your location:
Alternatively, you can make a copy of this below document, fill it out, and send it to our email: [email protected]:
Last updated
Was this helpful?